News detail
NewsCurrent position > News detail

Eh Mass Flow Meter Solutions: Accurate Density and Temperature Output

『Eh Mass Flow Meter Solutions: Accurate Density and Temperature Output』Related information(v cone flow meter|rotary gas meter|gallon meter|gear meter|metal tube rotameter|glass tube rotameter|nutating disk meter|transit time ultrasonic flow meter|wedge flow meter|pd meters|hydraulic flow meter|ultrasonic water flow meter|water flow meter|air flow meter|magnetic water flow meter|oxygen flow meter|gas flow meter|argon flow meter|air velocity meter|gasoline flow meter|fuel flow meter|ultrasonic water meter|digital water meter|nitrogen flow meter|solid flow meter|Oxygen tank flow meter|digital water flow meter|diesel fuel flow meter|steam flow meter|02 flow meter|compressed air flow meter|oil flow meter|liquid flow meter)

Quick Answer

Silver Automation Instruments supplies Coriolis mass flow meters that deliver mass flow, density, and temperature from one sensor. Standard density accuracy is ±0.0005 g/cm³ and standard temperature accuracy is ±0.5 °C. Send your fluid, pipe size, pressure, temperature, and flow range for a specific model quote.


Eh Mass Flow Meter Solutions: Accurate Density and Temperature Output

Many engineers search for Eh mass flow meter solutions with accurate density and temperature output. Silver Automation Instruments supplies a Coriolis mass flow meter for the same measurement task. One sensor reports mass flow in kg/h, density in g/cm³, and process temperature in °C.


We have installed these meters in oil and gas, chemical, food and beverage, water and wastewater, and marine sites. One meter reporting mass flow, density, and temperature reduces wiring, spare parts, and calibration time. The same meter also removes the need for a separate density analyzer on many process lines.


We supply end users and distributors in Southeast Asia, Oceania, Latin America, Africa, and the Middle East. These meters are often used in crude oil blending, diesel and fuel oil transfer, food syrup batching, chemical reactor feed, and desalination plants.


Outputs and Transmitter Options

Every Silver Automation Instruments Coriolis mass flow meter can be ordered with 4-20 mA HART output. Pulse output is available for batching. RS485 Modbus RTU works well for PLC and DCS integration. For hazardous areas, select an ATEX Zone 1 approved transmitter version.


Because density and temperature output comes from the same device, fuel blending, syrup concentration, and chemical dosing become easier to control. The internal PT100 sensor measures temperature and the transmitter calculates density from tube oscillation.


Accuracy, Sizing, and Materials

Standard mass flow accuracy is ±0.1 percent of rate for liquids and ±0.35 percent of rate for gas. Density accuracy reaches ±0.0005 g/cm³ on standard models. Temperature accuracy is ±0.5 °C. We cover line sizes from DN10 to DN200. DN3 and DN6 meters are available for low flow pilot plants.


Standard wetted parts are 316L stainless steel. Hastelloy C22 and titanium are optional for aggressive fluids. Process temperature covers -50 °C to 150 °C on standard units. High temperature versions extend to

Eh Mass Flow Meter Solutions: Accurate Density and Temperature Output
200 °C for hot oil and certain chemical processes. Pressure ratings include PN40, PN63, Class 150, and Class 300.


We do not quote a meter without your process data. Send us your pressure in bar, temperature in °C, pipe size DN, and flow range in kg/h. We will check viscosity in cP, conductivity in µS/cm, and gas content. Then we recommend a DN15, DN25, DN50, DN80, or DN100 meter with the right wetted parts.


Customer Site Examples

For a seawater desalination plant in Oman, a DN80 meter with 316L stainless steel wetted parts measured brine density and reverse osmosis feed temperature. For a paint manufacturer in Vietnam, a DN25 meter with Hastelloy C22 wetted parts handled solvent-based coating at 45 °C. A dairy in New Zealand uses a DN40 meter to measure milk concentrate density and temperature before spray drying.


Most engineers skip material compatibility during first selection. But material choice controls meter life and measurement stability. Tell us if your fluid contains chlorides, acids, or abrasive solids. We specify the correct sensor body and avoid early failure.


FAQs

What is the density accuracy of Silver Automation Instruments Coriolis mass flow meters? Standard density accuracy is ±0.0005 g/cm³. Density output at this accuracy works for concentration control, blending, and quality checks on liquids.


Does the meter output density and temperature at the same time? Yes. The transmitter reports mass flow, volumetric flow, density, and temperature over 4-20 mA HART, RS485 Modbus RTU, or pulse output.


Can I use the meter in a hazardous area? Yes. Order the ATEX Zone 1 approved transmitter version. We also supply flameproof and intrinsically safe options for gas and chemical sites.


What line sizes are available? Standard sizes are DN10, DN15, DN25, DN40, DN50, DN80, DN100, DN150, and DN200. DN3 and DN6 meters are available for low flow applications.


What information do you need for a quote? Send your fluid name, pressure in bar, temperature in °C, pipe size DN, and flow range in kg/h. We will reply with a model number, accuracy statement, and price.


Contact Silver Automation Instruments for a firm quote. Tel: +86-25-68650347. WhatsApp: +86-25-52155837. WeChat: +86 15365082610. You can also visit flow-meter.com.au.

『SILVER Official Website SERVICE』

Copyright2026SILVER E-Commerce
+86 15365082610